Double Shear Beam Load Cells

Double shear beam load cells are built for high-capacity structures such as silos, tanks, hoppers and weighbridges. Their robust format supports heavy loads when installed in the correct mounting arrangement.

The Laumas DTL and DTX ranges cover metric and manufacturer-rated imperial capacities. Select by working load, support layout, dimensions, mounting hardware and compatibility with the weighing electronics.

Filters

Sort by:

2 products

Laumas DTX Double Shear Beam Load Cell
Laumas DTL Double Shear Beam Load Cell

Further Reading

Double shear beam selection

A double shear beam design carries load through two shear sections, providing a robust weighing point for heavy structures. It is commonly used beneath large vessels, silos, hoppers and vehicle-weighing platforms.

Capacity should be calculated at each support using the dead weight and maximum contents, with allowance for uneven loading and movement. The mounting arrangement must transfer force correctly while controlling uplift and lateral movement where required.

Existing installations should be checked for corrosion, damaged restraints, cable condition and mechanical alignment before a replacement is commissioned.

Stable structural weighing

The robust sensor format suits structures with high point loads, provided the supports and mounting assemblies distribute the load as intended.

System compatibility

Check excitation, rated output, wiring and junction-box requirements against the connected indicator or transmitter.

Installation factors

Allow for structural movement, restraint, uplift protection, cable routing and access for inspection and calibration.

Learn more

Typical industrial applications

These sensors are intended for heavier fixed structures where each support carries a substantial share of the total load.

Silo and vessel weighing

Large silos and process vessels can be weighed through several supported points for stock monitoring, batching and process control.

Hopper weighing systems

Hopper systems use the measured weight to manage filling, discharge and material usage while the vessel remains installed.

Industrial platforms

Heavy platforms and weighbridge structures can use double shear beam sensors where the load is spread across multiple robust weighing points.

Process weighing upgrades

When upgrading an older system, the new sensor must fit the existing structure and work with the junction box and weighing electronics.

How to choose

Calculate the load at each support, then confirm mounting, dimensions, environmental protection and electrical output.

Check capacity and support points

Include the structure, maximum contents and any uneven distribution. Do not assume every support will carry exactly the same load.

Confirm mounting arrangement

Use the specified mounting arrangement and check restraints, uplift protection and freedom for normal thermal movement.

Match the electrical output

Match excitation, rated output, wiring and cable to the existing junction box, indicator or transmitter.

Review the environment

Consider water, corrosion, temperature, traffic, vibration and the practical access needed for inspection and replacement.

Double shear beam FAQs

These are the main checks for selecting or replacing a double shear beam weighing point.