M2 Test Weights

Compare Kern M2 test weights for weighing checks where wider reference-weight tolerances are acceptable. Choose individual stainless steel masses, boxed sets or cast iron blocks.

View Products

Need Help Choosing M2 Weights?

Send GNW the scale or balance model, test loads, permitted error and certificate requirements.
Contact GNW

Filters

Sort by:

Further Reading

Looking After M2 Reference Weights

Keep weights clean, dry and protected. Inspect lacquered cast iron for corrosion, damage or material loss, and use handling equipment suited to the mass. Contamination and damage can change the reference load.

Keep each weight’s identity and calibration records with your check results. Set recalibration intervals around use and handling conditions. Routine checks monitor an instrument at selected loads; they do not replace full calibration.

Individual Stainless Steel Weights

Choose one nominal mass from 1 g to 10 kg for a repeated test point or to extend an existing reference set.

Boxed M2 Sets

Compare ranges starting at 1 g and check the included masses, repeated values and wooden or aluminium case.

Cast Iron Blocks

Choose standard or Eco blocks at 5, 10, 20 or 50 kg. Compare dimensions and handling requirements as well as price.

Learn more

M2 Test Weight Applications

Use reference weights at defined loads, with acceptance limits set by your weighing procedure.

Routine Weighing Checks

Compare the instrument indication with an identified reference at a repeated load.

Production Quality Control

Check equipment at loads relevant to the components, packs or batches being weighed.

Checks After Maintenance

Repeat established loads after service or relocation, once the equipment has stabilised.

Recorded Test Points

Keep a consistent set of test masses and record results against your permitted limits.

How to Choose M2 Test Weights

Start with the permitted error, then compare masses, format, storage and calibration.

Confirm the Tolerance

Compare M2 permissible weight tolerance and calibration uncertainty with the error allowed in your check. Do not choose by display divisions alone.

Select the Masses

Use an individual weight for one repeated load or a set for several points. Check every included mass and any combinations required by your procedure.

Compare Design and Storage

Sets include their stated case. Matching plastic boxes are optional for Kern individual knob and milligram weights where offered. The block and check-weight listings have no selectable case option.

Choose the Certificate

Kern offers optional DAkkS calibration for the selected weight or set. The weight class and certificate are separate choices. Select No without an optional certificate or Yes – DAkkS traceable to include it.

Calibrated Pressure Gauges

Every gauge in this range can be supplied as a calibrated pressure gauge, ready for your quality records from day one. 

Select "Yes" under Calibration Certificate and we check the gauge against traceable reference equipment and issue the certificate ourselves. Our GNW200 digital gauges include a traceable certificate as standard.

M2 Test Weights FAQs

Answers about weight class, set contents, calibration and storage.

Blog posts

View all
Pressuretypes of pressure gauges in a boiler room

Different Types Of Pressure Gauges

Pressure gauges are often a standard regulation across many industries; that's why GNW offers a diverse product range. This article will take a closer look into the types of pressure gauges we have...

RefractometersKern digital handheld refractometer with numerical display and sample prism

Which Refractometer Do I Need? A Practical Buyer’s Guide

Testing honey, coolant, coffee or brewing wort? Learn which refractometer scales and ranges matter, compare analogue and digital options, and find a suitable Kern model.

CalibrationWhy Is Calibration Important? A Guide to Instrument Calibration

Why Is Calibration Important? A Guide to Instrument Calibration

Understand why instrument calibration matters, what a calibration certificate shows, and when traceable or UKAS-accredited calibration may be required.