Kern E2 Milligram Test Weight Sets


Choose a Kern E2 milligram set covering 1–500 mg. Platelet weights are available in plastic or aluminium cases; the wire set comes in a plastic case.

Choose the mass and tolerance

E2 identifies the weight accuracy class. Match the nominal masses, permissible tolerances and required calibration uncertainty to your weighing procedure. The same class will not suit every instrument.

Calibration and storage

Choose No without an optional certificate or Yes – DAkkS traceable to include Kern DAkkS calibration. The selected set includes its specified protective case. No separate case charge applies.

For advice, send GNW your instrument model, working loads and permitted error. Browse our test weights.

Model: 318-22 | 1 mg - 500 mg | plastic case

Model

Calibration Certificate: No

Calibration Certificate

Why is calibration important?
Sale price£325.00

Tax excluded. Shipping calculated at checkout

Estimated delivery: Approx. 5 working days.

Ask GNW a Question

Need help choosing the correct instrument? Send our team your question.

Product: Kern E2 Milligram Test Weight Sets

Learn more

Product specification

Compare model specifications.

Kern model 318-22 (plastic case); 318-226 (aluminium case) 318-42 (plastic case)
Nominal mass range 1 mg - 500 mg 1 mg - 500 mg
OIML class E2 E2
Weight material stainless steel polished stainless steel polished
Design Platelet Wire
Included case plastic case; aluminium case plastic case
Number of weights 318-22: 12; 318-226: 13 318-42: 12
Case dimensions (W × D × H) 318-22: 136×53×22 mm; 318-226: 165×158×37 mm 318-42: 136×53×22 mm

Learn more

Applications

Laboratory balance checks

Use suitable E2 references where their tolerance and calibration uncertainty meet your laboratory’s acceptance limits.

Working-load checks

Choose masses that represent the loads you actually weigh.

Checks after maintenance

Repeat established test points after service or relocation, once the equipment has stabilised.

Quality-control records

Record the weight identity and certificate details with your checking results.

Features

E2 accuracy class

Compare the permissible tolerance for each mass with your allowed weighing error.

Milligram-only sets

Reference masses from 1 to 500 mg in the protective case stated for the selected model.

Included case

The selected set includes its specified protective case. No separate case charge applies.

DAkkS calibration available

Add the supplier certificate for the selected weight or set when your quality procedure requires it.

FAQs

Need more help? Contact our sales team.
CONTACT US